Trane Yhc060f

broken image


As an established heating & cooling contractor serving the Elkhorn, Omaha, La Vista, Papillion, Blair, Council Bluffs area, we work on RTUs which provide heating and cooling for commercial applications in the Omaha metro area. For commercial maintenance personnel or others who would like to identify the various technical components within a particular Trane 13 or 16 SEER RTU, this blog will help in decoding the model number to identify the technical contents of the Trane roof top unit. Call us today at 402-238-2425.

YHC048F -YHC060F YHC072F -YHC102F. Trane, and may not be used or reproduced in whole or in part without written permission.Trane reserves the right. Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equip.

NOTE: This information has not been certified by the manufacturer. ENSURE that you verify all of this model number information with the manufacturer before using this information to make equipment selection or repair decisions.

Digit 1 – Unit Type

T DX Cooling

Y DX Cooling, Gas Heat

Digit 2 – Efficiency

S Standard Efficiency

H High Efficiency

Digit 3 – Airflow

C Convertible

Digit 4, 5, 6 – Nominal Gross Cooling Capacity (MBh)

033 3 Ton (13 SEER)

036 3 Ton

043 4 Ton (13 SEER)

048 4 Ton

060 5 Ton

063 5 Ton (13 SEER)

072 6 Ton

074 6 Ton, Dual Compressor

090 7.5 Ton, Single Compressor

092 7.5 Ton, Dual Compressor

102 8.5 Ton

120 10 Ton

Digit 7 – Major Design Sequence

E R-410 Refrigerant

F Microchannel Type Condenser Coils [24]

G Microchannel Type Evaporator and Condenser Coils

Digit 8 – Voltage Selection

1 208/230/60/1

3 208-230/60/3

4 460/60/3

W 575/60/3

Digit 9 – Unit Controls

E Electromechanical

R ReliaTel Microprocessor

Digit 10 – Heating Capacity

Note: The below are applicable to Digit 1, T models only

0 No Electric Heat

A 5kW (1 phase) [1]

B 6kW (3 phase)

C 9kW (3 phase)

D 10kW (1 phase) [1]

E 12kW (3 phase)

F 14kW (1 phase) [1]

G 18kW (1&3 phase)

J 23kW (3 phase)

K 27kW (3 phase)

N 36kW (3 phase)

P 54kW (3 phase)

Note: The below are applicable to Digit 1, Y models only

L Low Heat

M Medium Heat

H High Heat

X Low Heat, Stainless Steel Heat Exchanger

Y Medium Heat, Stainless Steel Heat Exchanger

Z High Heat, Stainless Steel Heat Exchanger

Digit 11 – Minor Design Sequence

A First Sequence [21]

B Second Sequence [20]

Digit 12, 13 – Service Sequence

** Factory Assigned

Digit 14 – Fresh Air Selection

0 No Fresh Air

A Manual Outside Air Damper 0-50% [4]

B Motorized Outside Air Damper 0-50% [29]

Yhc

C Economizer, Dry Bulb 0-100% without Barometric Relief [7]

D Economizer, Dry Bulb 0-100% with Barometric Relief [7]

E Economizer, Reference Enthalpy 0-100% without Barometric Relief [3,7]

F Economizer, Reference Enthalpy 0-100% with Barometric Relief [3,7]

G Economizer, Comparative Enthalpy 0-100% without Barometric Relief [3,7]

H Economizer, Comparative Enthalpy 0-100% with Barometric Relief [3,7]

K Low Leak Economizer with Barometric Relief

M Low Leak Economizer with Reference Enthalpy with Barometric Relief

P Low Leak Economizer with Comparative Enthalpy with Barometric Relief

Digit 15 – Supply Fan/Drive Type/Motor

0 Standard Drive [6]

1 Oversized Motor

2 Optional Belt Drive Motor [18]

6 Single Zone VAV [27, 34]

7 Multiple-Speed Indoor Fan [28]

E Hinged Access Panels/2' Merv 13 Filters

Digit 16 – Hinged Service Access/Filters

0 Standard Panels/Standard Filters

A Hinged Access Panels/Standard Filters

B Standard Panels/2' Merv 8 Filters

C Hinged Access Panels/2' Merv 8 Filters

D Standard Panels/2' Merv 13 Filters

E Hinged Access Panels/2' Merv 13 Filters

Digit 17 – Condenser Coil Protection

0 Standard Coil

1 Standard Coil with Hail Guard

2 Black Epoxy pre-Coated Condenser Coil [26]

3 Black Epoxy pre-Coated Condenser Coil with Hail Guard26

4 CompleteCoat Condenser Coil

5 CompleteCoat Condenser Coil with Hail Guard

Digit 18 – Through-the-Base Provisions

Note: The below are applicable to Digit 1, T or Y models

0 No Through-the-Base Provisions

A Through-the-Base Electric [8]

Note: The below are applicable to Digit 1, Y models only

B Through-the-Base Gas Piping [16]

C Through-the-Base Electric and Gas Piping [16]

Digit 19 – Disconnect/Circuit Breaker (three-phase only)

0 No Disconnect/No Circuit Breaker

1 Unit Mounted Non-Fused Disconnect [8]

2 Unit Mounted Circuit Breaker8

Digit 20 – Convenience Outlet

0 No Convenience Outlet

A Unpowered Convenience Outlet

B Powered Convenience Outlet (three-phase only [9]

Digit 21 – Communication Options [3]

0 No Communications Interface

1 Trane Communications Interface

Trane yhc060f4rha

2 LonTalk Communications Interface

3 Novar 2024 Controls [31]

4 Novar 3051 Controls Without Zone Sensor [31]

5 Novar 3051 Controls Interface with DCV [31]

6 BACnet Communications Interface

7 Air-Fi Wireless Communications [35]

Digit 22 – Refrigeration System Options

0 Standard Refrigeration System [10]

B Dehumidification Option [22,23]

Digit 23 – Refrigeration Controls

Note: The below are applicable to Digit 7 = E, F, G

0 No Refrigeration Control5

1 Frostat [11, 30]

2 Crankcase Heater [2]

3 Frostat11, 30 and Crankcase Heater [2]

Digit 24 – Smoke Detector [17]

0 No Smoke Detector

A Return Air Smoke Detector [12, 13]

B Supply Air Smoke Detector

C Supply and Return Air Smoke Detectors [12, 13]

D Plenum Smoke Detector

Digit 25 – System Monitoring Controls

0 No Monitoring Control [14]

1 Clogged Filter Switch [14]

2 Fan Failure Switch [14]

3 Discharge Air Sensing Tube [14]

4 Clogged Filter Switch and Fan Failure Switch [14]

5 Clogged Filter Switch and Discharge Air Sensing Tube [14]

6 Fan Failure Switch and Discharge Air Sensing Tube [14]

7 Clogged Filter Switch, Fan Failure Switch and Discharge Air Sensing Tube [14]

8 Novar Return Air Sensor (NOVAR 2024) [15, 31]

9 Novar Zone Temp Sensor (NOVAR 3051) [19, 31]

A Condensate Drain Pan Overflow Switch

B Clogged Filter Switch [14] and Condensate Drain Pan Overflow Switch

C Fan Failure Switch [14] and Condensate Drain Pan Overflow Switch

D Discharge Air Sensing [14] and Condensate Drain Pan Overflow Switch

E Clogged Filter Switch [14], Fan Failure Switch [14] and Condensate Drain Pan Overflow Switch

F Clogged Filter Switch [14], Discharge Air Sensing Tube [14] and Condensate Drain Pan Overflow Switch

G Fan Failure Switch [14] Discharge Air Sensing Tube [14] and Condensate Drain Pan Overflow Switch

H Clogged Filter Switch [14], Fan Failure Switch14 Discharge Air Sensing [14] and Condensate Drain Pan Overflow Switch

Digit 26 – System Monitoring Controls

0 No Monitoring Controls

A Demand Control Ventilation (CO2) [32, 33]

B Low Leak Economizer with FDD (Fault Detection & Diagnostics)

C FDD (Fault Detection & Diagnostics) with DCV (Demand Control Ventilation)

Digit 27 – Unit Hardware Enhancements
Yhc060f

C Economizer, Dry Bulb 0-100% without Barometric Relief [7]

D Economizer, Dry Bulb 0-100% with Barometric Relief [7]

E Economizer, Reference Enthalpy 0-100% without Barometric Relief [3,7]

F Economizer, Reference Enthalpy 0-100% with Barometric Relief [3,7]

G Economizer, Comparative Enthalpy 0-100% without Barometric Relief [3,7]

H Economizer, Comparative Enthalpy 0-100% with Barometric Relief [3,7]

K Low Leak Economizer with Barometric Relief

M Low Leak Economizer with Reference Enthalpy with Barometric Relief

P Low Leak Economizer with Comparative Enthalpy with Barometric Relief

Digit 15 – Supply Fan/Drive Type/Motor

0 Standard Drive [6]

1 Oversized Motor

2 Optional Belt Drive Motor [18]

6 Single Zone VAV [27, 34]

7 Multiple-Speed Indoor Fan [28]

E Hinged Access Panels/2' Merv 13 Filters

Digit 16 – Hinged Service Access/Filters

0 Standard Panels/Standard Filters

A Hinged Access Panels/Standard Filters

B Standard Panels/2' Merv 8 Filters

C Hinged Access Panels/2' Merv 8 Filters

D Standard Panels/2' Merv 13 Filters

E Hinged Access Panels/2' Merv 13 Filters

Digit 17 – Condenser Coil Protection

0 Standard Coil

1 Standard Coil with Hail Guard

2 Black Epoxy pre-Coated Condenser Coil [26]

3 Black Epoxy pre-Coated Condenser Coil with Hail Guard26

4 CompleteCoat Condenser Coil

5 CompleteCoat Condenser Coil with Hail Guard

Digit 18 – Through-the-Base Provisions

Note: The below are applicable to Digit 1, T or Y models

0 No Through-the-Base Provisions

A Through-the-Base Electric [8]

Note: The below are applicable to Digit 1, Y models only

B Through-the-Base Gas Piping [16]

C Through-the-Base Electric and Gas Piping [16]

Digit 19 – Disconnect/Circuit Breaker (three-phase only)

0 No Disconnect/No Circuit Breaker

1 Unit Mounted Non-Fused Disconnect [8]

2 Unit Mounted Circuit Breaker8

Digit 20 – Convenience Outlet

0 No Convenience Outlet

A Unpowered Convenience Outlet

B Powered Convenience Outlet (three-phase only [9]

Digit 21 – Communication Options [3]

0 No Communications Interface

1 Trane Communications Interface

2 LonTalk Communications Interface

3 Novar 2024 Controls [31]

4 Novar 3051 Controls Without Zone Sensor [31]

5 Novar 3051 Controls Interface with DCV [31]

6 BACnet Communications Interface

7 Air-Fi Wireless Communications [35]

Digit 22 – Refrigeration System Options

0 Standard Refrigeration System [10]

B Dehumidification Option [22,23]

Digit 23 – Refrigeration Controls

Note: The below are applicable to Digit 7 = E, F, G

0 No Refrigeration Control5

1 Frostat [11, 30]

2 Crankcase Heater [2]

3 Frostat11, 30 and Crankcase Heater [2]

Digit 24 – Smoke Detector [17]

0 No Smoke Detector

A Return Air Smoke Detector [12, 13]

B Supply Air Smoke Detector

C Supply and Return Air Smoke Detectors [12, 13]

D Plenum Smoke Detector

Digit 25 – System Monitoring Controls

0 No Monitoring Control [14]

1 Clogged Filter Switch [14]

2 Fan Failure Switch [14]

3 Discharge Air Sensing Tube [14]

4 Clogged Filter Switch and Fan Failure Switch [14]

5 Clogged Filter Switch and Discharge Air Sensing Tube [14]

6 Fan Failure Switch and Discharge Air Sensing Tube [14]

7 Clogged Filter Switch, Fan Failure Switch and Discharge Air Sensing Tube [14]

8 Novar Return Air Sensor (NOVAR 2024) [15, 31]

9 Novar Zone Temp Sensor (NOVAR 3051) [19, 31]

A Condensate Drain Pan Overflow Switch

B Clogged Filter Switch [14] and Condensate Drain Pan Overflow Switch

C Fan Failure Switch [14] and Condensate Drain Pan Overflow Switch

D Discharge Air Sensing [14] and Condensate Drain Pan Overflow Switch

E Clogged Filter Switch [14], Fan Failure Switch [14] and Condensate Drain Pan Overflow Switch

F Clogged Filter Switch [14], Discharge Air Sensing Tube [14] and Condensate Drain Pan Overflow Switch

G Fan Failure Switch [14] Discharge Air Sensing Tube [14] and Condensate Drain Pan Overflow Switch

H Clogged Filter Switch [14], Fan Failure Switch14 Discharge Air Sensing [14] and Condensate Drain Pan Overflow Switch

Digit 26 – System Monitoring Controls

0 No Monitoring Controls

A Demand Control Ventilation (CO2) [32, 33]

B Low Leak Economizer with FDD (Fault Detection & Diagnostics)

C FDD (Fault Detection & Diagnostics) with DCV (Demand Control Ventilation)

Digit 27 – Unit Hardware Enhancements

0 No Enhancements

1 Stainless Steel Drain Pan

Digit 31 – Advanced Unit Controls

0 Standard Unit Controls

1 Human Interface

Model Number Notes

1 Available on 3 to 5 ton models.

2 Crankcase heaters are optional on (T,Y)SC (036, 048, 060, 072, 090, 102, 120); standard on (T,Y)HC (036, 048, 060, 072, 074, 092, 102, 120).

3 Not available with electromechanical controls.

4 Manual outside air damper will ship factory supplied within the unit, but must be field installed.

5 High pressure control is standard on all units.

6 Multi-speed, direct drive motor with no belt drive option is standard on 3 to 5 ton, standard efficiency, 13/14 SEER units. Multi-speed, direct drive motor with a belt drive option is available for 3 to 5 ton, 15 SEER units. On 6 to 10 tons, multispeed direct drive is standard on all 10 ton and 6 (074) to 8.5 ton high efficiency. Belt drive is standard on all other units.

Digit 15 = 0

Standard Efficiency

3 Phase (3 to 5 Ton) = Multispeed Direct Drive Motor

3 Phase (6 to 8.5 Ton) = Belt Drive

3 Phase (10 Ton) = Ultra High Efficiency Direct Drive Plenum Fan

High Efficiency

1 Phase = High Efficiency Multispeed Direct Drive Motor

3 Phase (3 to 5 Ton) = High Efficiency Multispeed Direct Drive Motor

3 Phase (3 to 5 Ton w/Dehumidification) = Belt Drive Motor

3 Phase [6 (074) to 10 Ton] = Ultra High Efficiency Direct Drive Plenum Fan

7 Economizer with barometric relief is for downflow configured units only. Order economizer without barometric relief for horizontal configuration. Barometric relief for horizontal configured units must be ordered as field installed accessory.

8 Through-the-base electric required when ordering disconnect/circuit breaker options.

9 Requires use of disconnect or circuit breaker.

Not Available

Standard Efficiency

3 to 5 Tons and 10 Ton w/575V

High Efficiency

3 to 5 Tons w/Standard Indoor Motor w/460V

High Efficiency 575V

10 Standard metering devices are TXVs.

11 Frostat cannot be field installed in electro-mechanical units.

12 The return air smoke detector may not fit up or work properly on the Precedent units when used in conjunction with 3rd party accessories such as bolt on heat wheels, economizers and power exhaust. Do not order the return air smoke detectors when using this type of accessory.

13 Return air smoke detector cannot be ordered with Novar controls.

14 These options are standard when ordering Novar controls.

15 This option is used when ordering Novar controls.

16 Includes gas piping and shutoff (field assembly required).

17 Not available with high temperature duct sensor accessory.

18 Digit 15 = 2

Standard Efficiency

3 Phase = Not Available

High Efficiency

1 Phase = Not Available

3 Phase (3 to 5 tons) = May be ordered

3 Phase (3 to 5 tons w/dehumidification) = Not Available

3 Phase (6 to 10 tons) = Not Available

19 Novar sensor utilized with Digit 21 = (4) Novar 3051 controls without zone sensor.

20 Available for gas/electric, 3 to 5 tons high efficiency, single phase models.

21 Available for all models except gas/electric, 3 to 5 tons high efficiency, single phase.

22 Requires selection of 2' pleated filters (option B or C) for Digit 16.

23 Not available on all single phase or standard efficiency.

24 Standard on T/YSC 6, 7.5 (single and dual systems), 8.5, 10 ton standard efficiency models and T/YHC 4, 5, 6, 7.5, 10 ton MCHE high efficiency models (except for 4, 5, 6 ton dehumidification models).

25 Not available on high efficiency 575V.

26 Epoxy coil and epoxy with hail guard options are not available for units with microchannel condenser coil.

27 Single zone VAV is only available on 6 to 10 tons high efficiency and 10 ton standard efficiency products with ReliaTel controls.

28 Multi-speed indoor fan available only on 6, 7.5, & 8.5 tons high efficiency, and 10 ton products with ReliaTel controls.

29 Motorized outside air damper is not available on multi-speed or SZVAV (single zone Variable air volume) products.

30 Frostat standard on Y/TSC033 to 063G electromechanical, multispeed and SZVAV (single zone Variable air volume) products.

31 Novar is not available with SZVAV products.

32 Demand control ventilation not available with electromechanical controls.

33 Demand control ventilation option includes wiring only. The CO2 sensor is a field-installed only option.

34 Discharge air sensing is also standard equipment on units with single zone and supply air temperature control VAV.

35 Must be used with BACnet open protocol.

For additional information on these roof top units, a Trane RTU Installation Manual is available here.

Additional information and product literature is available from the Trane website. The website may offer additional information above and beyond the Trane 13 or 16 SEER RTU model number decoding information provided in this blog. Higher efficiency furnaces within these RTUs have higher AFUE ratings.

Trane RTU Serial Number Can Reveal Year of Manufacture beyond Trane 13 or 16 SEER RTU Model Number Decoding

Beyond Trane 13 or 16 SEER RTU model number decoding information, there may be a need to determine the year of manufacture of various HVAC equipment. There is a useful website for obtaining this serial number information found at the Building Intelligence Center website athttp://www.building-center.org and this site does not require any logon to access the site. Just select the type of HVAC equipment of interest and then find the equipment brand which is listed by alphabetic order of the the first letter in the brand name. Select the desired brand of equipment from the drop down menu. Then the variety of serial number formats used by the particular brand are shown. The site shows how to decode the serial number to determine the year the equipment was manufactured.

Additional Information

Check out our Home Page here to learn more about us.

And for a list of maintenance items that homeowners can perform to keep their HVAC system running efficiently, refer to this blog.

For a description of what the MERV rating on air filters means, refer to this blog.

For a good discussion on what air filter would be best, refer to this blog.

And for information on the description of Trane furnace model numbers, refer to this blog. For a description of Armstrong furnace model numbers, refer to this blog. The content of these other blogs will contain similar information to the Trane 13 or 16 SEER RTU model number decoding that is provided in this current blog.

For a description of older Ruud UAKA air conditioner model number decoding, refer to this blog.

For a description of newer Trane 80% furnace model numbers, refer to this blog.

And for tips on troubleshooting a gas valve failure, refer to this blog.

For technical material on troubleshooting a low voltage transformer failure, refer to this blog.

For information on how to properly connect the primary side of a low voltage transformer on roof top units, refer to this blog. Once in a while we run into a RTU that makes use of electric heating elements instead of the normal gas heat. For information on such an older York Electric Heat RTU, refer to this blog. For a description of older York RTU model DCE model number decoding, refer to this blog.

To understand how to correct a phase monitor on a Trane roof top unit that is preventing a unit from operating, refer to this blog. And check out this blog on how to troubleshoot a RTU Gas Regulator Intermittent Failure.

Your Trusted Omaha HVAC Contractor

As a trusted Omaha roof top unit installation and repair contractor, call Accurate Heating & Cooling for all your Omaha RTU service, Omaha air conditioner service, Omaha furnace service, Omaha mini split service, Omaha geothermal unit service, and Omaha home comfort needs. We also professionally install hvac equipment. We are licensed, bonded, insured, and experienced. We also have the highest BBB rating available. Call us today at 402-238-2425.

Trane Geothermal/Water Source Outdoor Split Heat Pump XL Series T2GE 022-1854-02

Trane Geothermal/Water Source Heat Pump XL Series T1GX, T2GX 022-1853-01

Trane Geothermal/Water Source Heat Pump XL Series T2GY 022-1852-02

Trane Geothermal/Water Source Heat Pump XR Series T1GC 022-1851-01

Trane Geothermal Hydronic Heat Pump XL Series T2GWB 022-1850-01

Trane Geothermal Hydronic Heat Pump XL Series T1GW 022-1849-01

Trane Modular Multi-position Air Handler GAF2 Series 22-1862-01

Trane Replacement Condensing Unit Product & Performance Data XB 300 22-1861-01

Trane XT 95 Condensing, Direct Vent Gas-Fired Furnace TUH1 TDH1 22-1859-01

Trane Modular Multi-position Air Handlers GAF Series 2 22-1858-02

Trane Modular Multi-position Air Handlers GAT Series 22-1857-03

Trane Variable Speed Modular Multi-position Communicating Air Handlers 2-5 Tons TAM8 Series 22-1856-04

Trane Modular Multi-position Air Handlers TAM4 Series 22-1848-02

Trane Variable Speed Modular Multi-position Air Handlers 2-5 Tons TAM7 Series 22-1847-04

Trane Aluminum Cased Horizontal Flat, Heat Pump / Cooling Coils 2 – 5 Ton 4TXFH-CC/CZ 22-1846-01

Trane Modular Multi-position Air Handlers GAM5 Series 22-1845-08

Trane Split System Cooling Product Data XB13 4TTB Series 22-1843-10

Trane Split System Cooling Product Data XR 13 4TTR Series 22-1842-07

Trane Split System Cooling Product & Performance Data XB 300 4TTM Series 22-1841-05

Trane XC 95m Communicating Variable Speed, Modulating Condensing Gas Furnace TUHMB TDHMB 22-1840-06

Trane Aluminum Cased Cooling Coils 2 – 5 Ton 4CXC 22-1839-03

Trane XR 95 Condensing, Direct Vent Gas-Fired Furnace TUH1 TDH1 22-1836-07

Trane Split System Cooling Product Data XB14 4TTB4 22-1833-09

Trane Split System Heat Pump Product Data XR15 4TWR5 22-1832-10

Trane Split System Cooling Product Data XR15 4TTR5 22-1831-08

Trane 4WHC3024 through 4WHC3060 Packaged Horizontal – Over/Under Heat Pump 2 – 5 Ton 22-1830-04

Trane XC80 2-Stage, Communicating Variable Speed Gas Furnace TUD2 TDD2 22-1827-03

Trane Yhc060f1

Trane Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace XC80 22-1827-02

Trane XL20i Split System Heat Pump Product Data 4TWZ0 22-1826-09

Trane XL20i Split System Cooling Product Data 4TTZ0 22-1825-09

Trane Fan Powered and Bypass Humidifiers THUMD Series 22-1821-02

Trane Modular Variable Speed Air Handlers 4TEE Series 22-1819-04

Trane XV 95 Variable Speed Two Stage Condensing Gas-Fired Furnace TUH TDH Series 22-1814-07

Trane Aluminum Cased and Uncased Heat Pump / Cooling Coils 1 1/2 – 5 Ton 4TXA, 4TXC, 4TXC-CC 22-1813-06

Trane XV90i 90% 2-Stage, Variable Speed Gas-Fired Condensing Furnace with Whole House Air Cleaner TUX2 22-1803-05

Trane XV80i 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner TUD2 22-1802-03

Trane XL 15i Split System Heat Pump Product Data 4TWX5 22-1800-13

Trane 14 SEER Single Packaged Convertible Dual Fuel 4DCY4 22-1799-15

Trane 14 SEER Single Packaged Convertible Cooling 4TCY4 22-1796-13

Trane XR 13 Split System Heat Pump Product Data 4TWR3 22-1795-10

Trane XB 13 Split System Heat Pump Product Data 4TWB3 22-1793-12

Trane Three Phase Split System Heat Pump Product Data 4TWA3 22-1792-08

Trane Three Phase Split System Cooling Product Data 4TTA3 22-1791-10

Trane XR 13 Split System Cooling Product Data 4TTR3 22-1790-08

Trane XT 90 Condensing Gas Furnace TUX TDX 22-1786-06

Trane 13 SEER Single Packaged Convertible Gas/Electric 4YCX 22-1785-12

Trane 13 SEER Single Packaged Convertible Gas/Electric 4YCC3 22-1784-12

Trane 13 SEER Single Packaged Convertible Cooling 4TCX 22-1783-11

Trane 13 SEER Single Packaged Convertible Cooling 4TCC 22-1782-12

Trane 13 SEER Single Packaged Convertible Heat Pump 4WCX 22-1781-11

Trane 13 SEER Single Packaged Convertible Heat Pump 4WCC 22-1780-11

Trane XT 80 Gas-Fired Furnace TUD TDD 22-1779-06

Trane Vertical Upflow, Horizontal Left Air Handlers 2/4TGB 22-1778-06

Trane Cooling/Heat Pump Convertible Air Handlers 2/4TEH 22-1777-10

Trane Fresh Effects™ Energy Recovery Ventilator TERVR Series 22-1776-04

Trane Cooling/Heat Pump Convertible Air Handlers 2/4TEC 22-1774-17

Trane XB 13 Split System Heat Pump Product & Performance Data 2TWB 22-1771-04

Trane Three Phase Split System Cooling Product & Performance Data 2TTA3 22-1770-03

Trane XB 13 Split System Cooling Product & Performance Data 2TTB3 22-1769-06

Trane Yhc060f3rma

Trane Perfect Fit™ Electronic Air Cleaners & Filter media 22-1760-02

Trane XP80 / XV80 Oil-Fired Furnace THV TDF TLF TLR 22-1757-08

Trane XL16i Split System Heat Pump Product Data 4TWX 22-1754-17

Trane Yhc120f

Trane XL16i Split System Heat Pump, ComfortLink™ II and Charge Assist™ 4TWX 22-1754-10

Trane XL16i Split System Heat Pump Product Data 4TWX 22-1754-05A

Trane Vertical Upflow Air Handlers With Electric Heat TFB TFE 22-1753-06

Trane XL16i Split System Cooling Product Data 4TTX 22-1752-10

Trane Modular Variable Speed Air Handlers 4TEE 22-1717-10

Trane Two Stage Condensing Gas-Fired Furnace TUX TDX 22-1705-08

Trane XB 80 Induced Draft Gas Furnace TDE 22-1677-05

Trane XV 80 2-Stage, Variable Speed Gas-Fired Furnace TDD2 22-1673-07

Trane XR 80 Induced Draft Gas Furnace TDD1 22-1671-10

Trane XB 90 Condensing, Gas-Fired Furnace TDC1 22-1670-07

Trane XB 90 Condensing, Gas-Fired Furnace TUC1 22-1669-10

Trane XB 80 Induced Draft Gas Furnace TUE1 22-1666-07

Trane XV80 2-Stage, Variable Speed Gas-Fired Furnace TUD2 22-1650-13

Trane XR 80 Induced Draft Gas Furnace TUD1 22-1640-12

Trane XL 80 Gas-Fired Furnace TUD2 TDD2 22-1639-12

Trane Geothermal Split System Air Handler Product Data 022-1860-01

Trane Geothermal Indoor Split Heat Pump Product Data XL Series T1GN, T2GN 022-1855-01